Brand Name : CHX
Model Number : CHX-DM027
Certification : CE, RoHS
Place of Origin : CHINA
MOQ : 10pc
Price : Negotiation
Payment Terms : T/T, Western Union,Paypal,L/C
Supply Ability : 50000pcs/month
Delivery Time : 5-35days
Packaging Details : 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg
product name : Handheld Digital Multimeter
Model : CHX-DM027
Frequency range : 9.999Hz
Resolution : 0.001Hz
Accuracy : ±(1.0% of reading +3words)
Overload protection : 250V DC or AC (rms)
Input voltage range : 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
Ambient temperature : 23 ± 5 ℃
Automatic Range Infrared Themometer Capacitance Measurement
Description:
 - instrument for AC current, DC current, AC voltage sine wave true RMS, DC voltage, frequency, duty cycle, resistance, capacitance measurement and line off, diode testing, temperature measurement.
 - The instrument has an automatic range function.
 - The meter has a reading hold function.
 - The instrument has an automatic shutdown function.
Maintenance
 1.4.1 Do not attempt to open the bottom case to adjust or repair the instrument. This operation can only be performed by a technician who is fully aware of the instrument and the risk of electric shock.
 1.4.2 Before opening the instrument case or battery cover, remove the test leads from the circuit under test.
 1.4.3 In order to avoid false alarms that may cause errors, when the meter displays the "" symbol,Replace the battery immediately.
 1.4.4 Use a damp cloth and mild detergent to clean the meter, do not use abrasives or solvents.
 1.4.5 When the instrument is not in use, turn off the power and turn the range switch to the OFF position.
 1.4.6 If the instrument is not used for a long time, remove the battery to prevent damage to the instrument.
  
Technical indicators
  
 Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
 3.2.1 True rms zero input
 3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
 3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
 3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
  
  
  
 3.2.2 DC voltage
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.5% of reading + 5 words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(0.8% of reading + 5 words) | 
- Input impedance: 10MΩ
 - Maximum input voltage: 600V DC or 600V AC (rms)
 Note:
 In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
 This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
  
  
 3.2.3 AC voltage
  
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.8% of reading + 3words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(1.0% of reading + 10words) | 
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
 In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
 This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
  
  
  
 3.2.4 Alternating current
  
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.5% of reading +10words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.5% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
 10A range without insurance
 - Maximum input current: mA: 600mA DC or AC rms;
 10A: 10A DC or AC rms;
 When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
 - Frequency response: 40Hz ~ 1000Hz True RMS.
  
 3.2.5 DC
  
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.0% of reading +5words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.0% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
 10A range without insurance
 - Maximum input current: mA: 600mA DC or AC rms;
 10A: 10A DC or AC rms;
 When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
  
  
 3.2.6 Frequency
  
| Range | Resolution | Accuracy | 
| 9.999Hz | 0.001Hz | ±(1.0% of reading +3words) | 
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999kHz | 0.001kHz | |
| 99.99KHZ | 0.01kHZ | |
| 999.9KHZ | 0.1KHZ | |
| 9.999MHZ | 0.001MHZ | 
- Overload protection: 250V DC or AC (rms)
 - Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
  
  
 3.2.7 Duty cycle
  
| Range | Resolution | Accuracy | 
| 0.1 – 99.9% | 0.1% | ± 3.0% | 
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
  
  
Resistance
  
| Range | Resolution | Accuracy | 
| 600W | 0.1W | ±(0.8% of reading +3words) | 
| 6kW | 0.001kW | |
| 60kW | 0.01kW | |
| 600kW | 0.1kW | |
| 6MW | 0.001MW | ±(1.2% of reading +3words) | 
| 60MW | 0.01MW | 
- Open circuit voltage: approx. 1.0V
 - Overload protection: 250V DC or AC (rms)
  
  
Transistor test
| Range | Description | Test Conditions | 
| hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V | 
Capacitance
| Range | Resolution | Accuracy | 
| 9.999nF | 0.001nF | ±(4.0% of reading +3words) | 
| 99.99nF | 0.01nF | |
| 999.9nF | 0.1nF | |
| 9.999mF | 0.001mF | |
| 99.99mF | 0.01mF | |
| 999.9mF | 0.1mF | |
| 9.999mF | 0.001mF | ±(5.0% of reading +3words) | 
| 99.99mF | 0.01mF | Not calibrated | 
- Overload protection: 250V DC or AC (rms)
Temperature test
| Range | Accuracy | Resolution | 
| -20℃-300℃ | ±(1.0%+4d) | 1℃ | 
| 301℃-1000℃ | ±(1.9%+5d) | 1℃ | 
| -4℉-600℉ | ±(1.2%+6d) | 1℉ | 
| 601℉-1832℉ | ±(1.9%+6d) | 1℉ | 
- Overload protection: 250V DC or AC (rms)
|   | 
| Automatic Range LCD Digital Multimeter 9.999Hz 0.001Hz Resolution Images | 
 600uA Handheld Digital Multimeter AC DC 60V 600V 1000V Non Contact Voltage Test
                                                                                    
                        
                        
                        
                                                            600uA Handheld Digital Multimeter AC DC 60V 600V 1000V Non Contact Voltage Test
                                                    
                        
                     250V LCD Digital Multimeter Tester 10MΩ Overload protection
                                                                                    
                        
                        
                        
                                                            250V LCD Digital Multimeter Tester 10MΩ Overload protection
                                                    
                        
                     0.1V High Accuracy Digital Multimeter 600V 40Hz 1000Hz True RMS
                                                                                    
                        
                        
                        
                                                            0.1V High Accuracy Digital Multimeter 600V 40Hz 1000Hz True RMS
                                                    
                        
                     600kQ 6MQ 60MQ LCD Digital Multimeter 1000v Non Contact Voltage Test
                                                                                    
                        
                        
                        
                                                            600kQ 6MQ 60MQ LCD Digital Multimeter 1000v Non Contact Voltage Test
                                                    
                        
                     0.001V High Resolution 4000 Counts Multimeter 1000Hz True RMS NVC
                                                                                    
                        
                        
                        
                                                            0.001V High Resolution 4000 Counts Multimeter 1000Hz True RMS NVC
                                                    
                        
                     Automatic Shutdown LCD Digital Multimeter 100mF 6MΩ 60MΩ 600mA DC Current
                                                                                    
                        
                        
                        
                                                            Automatic Shutdown LCD Digital Multimeter 100mF 6MΩ 60MΩ 600mA DC Current
                                                    
                        
                     LCD Display 10 Amp Multimeter Overload Protection 0.500Kg
                                                                                    
                        
                        
                        
                                                            LCD Display 10 Amp Multimeter Overload Protection 0.500Kg
                                                    
                        
                     Professional LCD Digital Multimeter 1A 10A 1uF 10uF 100uF 1mF Multi Range AC
                                                                                    
                        
                        
                        
                                                            Professional LCD Digital Multimeter 1A 10A 1uF 10uF 100uF 1mF Multi Range AC
                                                    
                        
                     0.500Kg Professional Digital Multimeter 600V with Backlight
                                                                                    
                        
                        
                        
                                                            0.500Kg Professional Digital Multimeter 600V with Backlight
                                                    
                        
                     600mA 6A 10A Portable Digital Multimeter 600V RoHS Approved
                                                                                    
                        
                        
                        
                                                            600mA 6A 10A Portable Digital Multimeter 600V RoHS Approved